Trim Coil for WENDELSTEIN 7-X
![]() |
10 water-cooled non-planar trim coils to be installed inside plasma chamber of the German fusion experiment W7-X. The normal conducting coils are made out of a hollow copper conductor and are cooled by water. |
Customer: Max Planck Institute for Plasma Physics, Greifswald Division
Duration of project: 2004 - 2008
Technical Data of a Coil:
| Dimensions: | 2035 mm x 356 mm | |
| Weight: | ca. 200 kg | |
| Input Voltage: | -30 V - + 30 V | |
| Peak Current: | -3125 A - + 3125 A | |
| Inductivity: | 0,188 mH | |
| Mode of Operation: | AC& DC |